Go Chair® *FDA Class II Medical Device*

Go Chair® *FDA Class II Medical Device*

Regular price
$1,699.00
Sale price
$1,699.00
Regular price
Sold out
Unit price
per 

  • Choice of 6 colors
  • 18" x 17" or 20"x18", 5-point swivel seat with latch release
  • Increased 300 lb. weight capacity
  • Faster speed - up to 3.7 mph
  • Larger, 18 amp batteries
  • Improved agility - longer wheel base; wider stance; compact turning radius 25.4"
  • Dual swing-away, under seat storage bins
  • Larger, height & width adjustable armrests
  • Larger footplate
  • One hand feather-touch disassembly
  • 60" lap belt

* Pride FDA Class II Medical Devices are designed to aid individuals with mobility impairments.*  

  • Model Go Chair
  • Weight Capacity 300 lbs.
  • Turning Radius1 25.5"
  • Width1 22.5"
  • Length1,2 28.5" without front rigging
  • 33" with front rigging
  • Maximum Speed3 up to 3.7 mph
  • Ground Clearance1 1.8" at motor, 1.7" at anti-tip, 2.7" at foot bracket
  • Front Wheels 6" solid casters
  • Drive Wheels 9" solid
  • Rear Wheels 3" solid anti-tips
  • Standard Electronics 40 amp, PG GC3 (non-programmable)
  • Battery Size (2 required) 18 Ah, 12 V, deep-cycle
  • Standard Battery Charger Off-board, 2 amp
  • Per-Charge Range3,6 Up to 8.7 miles (std), 10.9 miles with extended range
  • Battery Weight5 14 lbs. each
  • Weight of Heaviest Piece4 36 lbs. (rear)
  • Standard Seat Weight 30 lbs.
  • Standard Seat Size Compact, Foldable (18"x17")
  • Medicare Code Coverage K0899 Power Mobility Device, not coded by DME PDAC or does not meet criteria
  • Warranty 5-year limited on frame;
  • 13-month limited on electronics;
  • 13-month limited on drive motors

Notes:
1 Due to manufacturing tolerances and continual product improvement, this specification can be subject to a variance of + or - 3 %. Dimensions listed are for power base only. Overall measurements will vary based on seating and accessory selections.
2 Without front riggings.
3 Varies with user weight, terrain, battery type, battery condition and tire pressure.
4 Does not include seat or battery weights.
5 Battery weight may vary based on manufacturer.
6 Tested in accordance with ANSI/RESNA, WC Vol. 2, Section 4 and ISO 7176-4 standards. Results derived from theoretical calculations based on battery specifications and drive system performance. Testing conducted at maximum weight capacities. This specification can be subject to a variance of +10%, -5%.
The information contained herein is correct at the time of publication; we reserve the right to alter specifications without prior notice.